>STANDARD PROCEDURE - TESTING FOR A SHORT TO GROUND ON FUSES POWERING SEVERAL LOADS</title><s1
><ptxt
>Refer to the wiring diagrams and disconnect or isolate all items on the suspected fused circuits.</ptxt></s1><s1
><ptxt
>Replace the blown fuse.</ptxt></s1><s1
><ptxt
>Supply power to the fuse by turning ON the ignition switch or re-connecting the battery.</ptxt></s1><s1
><ptxt
>Start connecting or energizing the items in the fuse circuit one at a time. When the fuse blows the circuit with the short to ground has been isolated.</ptxt></s1></servinfo>