<?xml version="1.0"?>
<?xml-stylesheet type="text/xsl" href="./twl_formatc.xsl"?>
<servinfo
releasenbr="1"
update="original"
id="m57bfdf5907d447fa4297ccb6e72c701"
><title
>STANDARD PROCEDURE - CONVENTIONAL BATTERY CHARGING</title><attention2
name="CAUTION"
><ptxt
>Vehicles equipped with a diesel engine utilize a unique spiral cell battery. This battery has a maximum charging voltage that must be used in order to restore the battery
to its full potential, failure to use the spiral cell battery charging procedure could result in damage to the battery or personal injury. <extxref
document="SOFTLINK"
extrefid="0851001360"
>(Refer
to 8 - ELECTRICAL/BATTERY SYSTEM/BATTERY - STANDARD PROCEDURE - SPIRAL CELL BATTERY CHARGING)</extxref> for the appropriate procedure.</ptxt></attention2><para
><ptxt
>Battery charging is the means by which the battery can be restored to its full voltage potential. A battery is fully-charged when:</ptxt></para><list1
enumtype="bullet"
><item
><ptxt
>Micro 420 battery tester indicates battery is OK.</ptxt></item><item
><ptxt
>Open-circuit voltage of the battery is 12.65 volts or above.</ptxt></item><item
><ptxt
>Battery passes Load Test multiple times.</ptxt></item></list1><attention1
name="WARNING"
><ptxt
>If the battery shows signs of freezing, leaking, loose posts, do not test, assist-boost, or charge. The battery may arc internally and explode. Personal injury and/or vehicle
damage may result.</ptxt></attention1><attention1
name="WARNING"
><ptxt
>Explosive hydrogen gas forms in and around the battery. Do not smoke, use flame, or create sparks near the battery. Personal injury and/or vehicle damage may result.</ptxt></attention1><attention1
name="WARNING"
><ptxt
>The battery contains sulfuric acid, which is poisonous and caustic. Avoid contact with the skin, eyes, or clothing. In the event of contact, flush with water and call a
physician immediately. Keep out of the reach of children.</ptxt></attention1><attention1
name="WARNING"
><ptxt
>If the battery is equipped with removable cell caps, be certain that each of the cell caps is in place and tight before the battery is returned to service. Personal injury
and/or vehicle damage may result from loose or missing cell caps.</ptxt></attention1><attention2
name="CAUTION"
><ptxt
>Always disconnect and isolate the battery negative cable before charging a battery. Do not exceed sixteen volts while charging a battery. Damage to the vehicle electrical
system components may result.</ptxt></attention2><attention2
name="CAUTION"
><ptxt
>Battery electrolyte will bubble inside the battery case during normal battery charging. Electrolyte boiling or being discharged from the battery vents indicates a battery
overcharging condition. Immediately reduce the charging rate or turn off the charger to evaluate the battery condition. Damage to the battery may result from overcharging.</ptxt></attention2><attention2
name="CAUTION"
><ptxt
>The battery should not be hot to the touch. If the battery feels hot to the touch, turn off the charger and let the battery cool before continuing the charging operation.
Damage to the battery may result.</ptxt></attention2><para
><ptxt
>After the battery has been charged to an open-circuit voltage reading of 12.4 volts or greater, retest the battery with the Micro 420 tester or perform a load test to determine the battery cranking
capacity. <extxref
document="SOFTLINK"
extrefid="0851001360"
>(Refer to 8 - ELECTRICAL/BATTERY SYSTEM/BATTERY - STANDARD PROCEDURE - USING MICRO 420 BATTERY TESTER)</extxref> for the proper battery test
procedures. If the battery passes a load test, return the battery to service. If the battery fails a load test, it is faulty and must be replaced.</ptxt></para><para
><ptxt
>Clean and inspect the battery hold downs, tray, terminals, posts, and top before completing battery service. <extxref
document="SOFTLINK"
extrefid="0851000390"
>(Refer to 8 - ELECTRICAL/BATTERY
SYSTEM - CLEANING)</extxref> for the proper battery system cleaning procedures. <extxref
document="SOFTLINK"
extrefid="0851000400"
>(Refer to 8 - ELECTRICAL/BATTERY SYSTEM - INSPECTION)</extxref> for the proper battery
system inspection procedures.</ptxt></para><servinfosub
id="c3f6c48504434769b46ee92b381071f9"
><title
>CHARGING A COMPLETELY DISCHARGED CONVENTIONAL BATTERY</title><para
><ptxt
>The following procedure should be used to recharge a completely discharged battery. Unless this procedure is properly followed, a good battery may be needlessly replaced.</ptxt></para><figure
figtype="1-column-portrait-no-fig-id"
id="id151726931"
><graphic
graphicname="7a026f13"
></graphic></figure><s1
><ptxt
>Measure the voltage at the battery posts with a voltmeter, accurate to 1/10 (0.10) volt. If the reading is below ten volts, the battery charging current will be low. It could take some time before
the battery accepts a current greater than a few milliamperes. Such low current may not be detectable on the ammeters built into many battery chargers.</ptxt></s1><s1
><ptxt
>Disconnect and isolate the battery negative cable. Connect the battery charger leads. Some battery chargers are equipped with polarity-sensing circuitry. This circuitry protects the battery charger
and the battery from being damaged if they are improperly connected. If the battery state-of-charge is too low for the polarity-sensing circuitry to detect, the battery charger will not operate. This makes
it appear that the battery will not accept charging current. See the instructions provided by the manufacturer of the battery charger for details on how to bypass the polarity-sensing circuitry.</ptxt></s1><s1
><ptxt
>Battery chargers vary in the amount of voltage and current they provide. The amount of time required for a battery to accept measurable charging current at various voltages is shown in the Charge
Rate Table. If the charging current is still not measurable at the end of the charging time, the battery is faulty and must be replaced. If the charging current is measurable during the charging time, the
battery may be good and the charging should be completed in the normal manner.<symbol
name="skip"
></symbol></ptxt></s1><table
frame="all"
pgwide="0"
id="e66ccade7313479fae52086d38f21d88"
><title
>CONVENTIONAL BATTERY CHARGE RATE TABLE</title><tgroup
xmlns:fo="http://www.w3.org/1999/XSL/Format"
xmlns:saxon="http://icl.com/saxon"
border-width.conditionality="retain"
font-size="7pt"
width="100%"
border-collapse="collapse-with-precedence"
table-omit-header-at-break="false"
border-width="1pt"
border-color="black"
border-style="solid"
space-after="6pt"
><table-column
column-number="1"
column-width="1.76in"
border-end-width="1pt"
border-end-color="black"
border-end-style="solid"
></table-column><table-column
column-number="2"
column-width="1.75in"
></table-column><thead
><row
><entry
valign="top"
align="center"
><ptxt
>Voltage</ptxt></entry><entry
valign="top"
align="center"
><ptxt
>Minutes</ptxt></entry></row></thead><tbody
><row
><entry
valign="top"
align="center"
><ptxt
>16.0 volts maximum</ptxt></entry><entry
valign="top"
align="center"
><ptxt
>up to 10 min.</ptxt></entry></row><row
><entry
valign="top"
align="center"
><ptxt
>14.0 to 15.9 volts</ptxt></entry><entry
valign="top"
align="center"
><ptxt
>up to 20 min.</ptxt></entry></row><row
><entry
valign="top"
align="center"
><ptxt
>13.9 volts or less</ptxt></entry><entry
valign="top"
align="center"
><ptxt
>up to 30 min.</ptxt></entry></row></tbody></tgroup></table></servinfosub><servinfosub
><title
>CHARGING TIME REQUIRED</title><para
><ptxt
>The time required to charge a battery will vary, depending upon the following factors:</ptxt></para><list1
enumtype="bullet"
><item
><ptxt
><emph
>Battery Capacity</emph> - A completely discharged heavy-duty battery requires twice the charging time of a small capacity battery.</ptxt></item><item
><ptxt
><emph
>Temperature</emph> - A longer time will be needed to charge a battery at -18° C (0° F) than at 27° C (80° F). When a fast battery charger is connected to a cold battery,
the current accepted by the battery will be very low at first. As the battery warms, it will accept a higher charging current rate (amperage).</ptxt></item><item
><ptxt
><emph
>Charger Capacity</emph> - A battery charger that supplies only five amperes will require a longer charging time. A battery charger that supplies twenty amperes or more will require a shorter
charging time.</ptxt></item><item
><ptxt
><emph
>State-Of-Charge</emph> - A completely discharged battery requires more charging time than a partially discharged battery. Electrolyte is nearly pure water in a completely discharged battery.
At first, the charging current (amperage) will be low. As the battery charges, the specific gravity of the electrolyte will gradually rise.</ptxt></item></list1><para
><ptxt
>The Conventional Battery Charging Time Table gives an indication of the time required to charge a typical battery at room temperature based upon the battery state-of-charge and the charger capacity.</ptxt></para><table
frame="all"
pgwide="0"
id="ga64d06bbf0b4487b170bc99a0c8d357"
><title
>CONVENTIONAL BATTERY CHARGING TIME TABLE</title><tgroup
xmlns:fo="http://www.w3.org/1999/XSL/Format"
xmlns:saxon="http://icl.com/saxon"
border-width.conditionality="retain"
font-size="7pt"
width="100%"
border-collapse="collapse-with-precedence"
table-omit-header-at-break="false"
border-width="1pt"
border-color="black"
border-style="solid"
space-after="6pt"
><table-column
column-number="1"
column-width="1.35in"
border-end-width="1pt"
border-end-color="black"
border-end-style="solid"
></table-column><table-column
column-number="2"
column-width="0.74in"
border-end-width="1pt"
border-end-color="black"
border-end-style="solid"
></table-column><table-column
column-number="3"
column-width="0.71in"
border-end-width="1pt"
border-end-color="black"
border-end-style="solid"
></table-column><table-column
column-number="4"
column-width="0.71in"
></table-column><thead
><row
><entry
valign="top"
align="center"
><ptxt
>Charging Amperage</ptxt></entry><entry
valign="middle"
align="center"
><ptxt
>5 Amps</ptxt></entry><entry
valign="middle"
align="center"
><ptxt
>10 Amps</ptxt></entry><entry
valign="middle"
align="center"
><ptxt
>20 Amps</ptxt></entry></row><row
><entry
valign="top"
align="center"
><ptxt
>Open Circuit Voltage</ptxt></entry><entry
valign="middle"
align="center"
colspan="3"
><ptxt
>Hours Charging @ 21° C (70° F)</ptxt></entry></row></thead><tbody
><row
><entry
valign="top"
align="center"
><ptxt
>12.25 to 12.49</ptxt></entry><entry
valign="top"
align="center"
><ptxt
>6 hours</ptxt></entry><entry
valign="top"
align="center"
><ptxt
>3 hours</ptxt></entry><entry
valign="top"
align="center"
><ptxt
>1.5 hours</ptxt></entry></row><row
><entry
valign="top"
align="center"
><ptxt
>12.00 to 12.24</ptxt></entry><entry
valign="top"
align="center"
><ptxt
>10 hours</ptxt></entry><entry
valign="top"
align="center"
><ptxt
>5 hours</ptxt></entry><entry
valign="top"
align="center"
><ptxt
>2.5 hours</ptxt></entry></row><row
><entry
valign="top"
align="center"
><ptxt
>10.00 to 11.99</ptxt></entry><entry
valign="top"
align="center"
><ptxt
>14 hours</ptxt></entry><entry
valign="top"
align="center"
><ptxt
>7 hours</ptxt></entry><entry
valign="top"
align="center"
><ptxt
>3.5 hours</ptxt></entry></row><row
><entry
valign="top"
align="center"
><ptxt
>Below 10.00</ptxt></entry><entry
valign="top"
align="center"
><ptxt
>18 hours</ptxt></entry><entry
valign="top"
align="center"
><ptxt
>9 hours</ptxt></entry><entry
valign="top"
align="center"
><ptxt
>4.5 hours</ptxt></entry></row></tbody></tgroup></table></servinfosub></servinfo>