<?xml version="1.0"?>
<?xml-stylesheet type="text/xsl" href="./twl_formatc.xsl"?>
<servinfo
releasenbr="1"
update="original"
id="jf794cb20946439285118c8bf2215bb3"
><title
>P0131-O2 SENSOR 1/1 CIRCUIT LOW</title><figure
figtype="2-column-portrait-no-fig-id"
id="k636adaaf4464309bbace557da81718a"
><graphic
graphicname="7a0338cc"
></graphic></figure><para
><ptxt
>For a complete wiring diagram <emph
>Refer to Section 8W</emph>.</ptxt></para><diagnostic
type="condition"
><condition
><spec
><list1
><item
><ptxt
><emph
>When Monitored:</emph></ptxt><para
><ptxt
>Engine running for less than 30 seconds and the O2 Sensor Heater Temperature is less than 251° C (484° F) with battery voltage greater 10.4 volts.</ptxt></para></item><item
><ptxt
><emph
>Set Condition:</emph></ptxt><para
><ptxt
>The oxygen sensor signal voltage is below 2.5196 volts for 6 seconds after starting engine. Two Trip Fault. Three good trips to turn off the MIL.</ptxt></para></item></list1><table
><tgroup
xmlns:fo="http://www.w3.org/1999/XSL/Format"
xmlns:saxon="http://icl.com/saxon"
border-width.conditionality="retain"
font-size="7pt"
width="100%"
border-collapse="collapse-with-precedence"
table-omit-header-at-break="false"
border-width="1pt"
border-color="black"
border-style="solid"
space-after="6pt"
table-layout="fixed"
><table-column
column-number="1"
column-width="proportional-column-width(396)"
></table-column><thead
><row
><entry
valign="bottom"
align="center"
><ptxt
><emph
>Possible Causes</emph></ptxt></entry></row></thead><tbody
><row
><entry
valign="top"
align="left"
><ptxt
>(K902) O2 RETURN UPSTREAM CIRCUIT SHORTED TO GROUND</ptxt></entry></row><row
><entry
valign="top"
align="left"
><ptxt
>(K41) O2 1/1 SIGNAL CIRCUIT SHORTED TO GROUND</ptxt></entry></row><row
><entry
valign="top"
align="left"
><ptxt
>(K41) O2 1/1 SIGNAL CIRCUIT SHORTED TO THE (K902) O2 RETURN UPSTREAM CIRCUIT</ptxt></entry></row><row
><entry
valign="top"
align="left"
><ptxt
>(K41) O2 1/1 SIGNAL CIRCUIT SHORTED TO THE (Z906) O2 1/1 HEATER GROUND CIRCUIT</ptxt></entry></row><row
><entry
valign="top"
align="left"
><ptxt
>O2 SENSOR</ptxt></entry></row><row
><entry
valign="top"
align="left"
><ptxt
>PCM</ptxt></entry></row></tbody></tgroup></table></spec><para
><ptxt
><emph
>Always perform the Pre-Diagnostic Troubleshooting procedure before proceeding. <extxref
document="SOFTLINK"
extrefid="0900000030"
>(Refer to 9 - ENGINE - DIAGNOSIS AND TESTING)</extxref>.</emph></ptxt></para></condition></diagnostic><diagnostic
type="test"
><?STEP 1------------------------------------------------------------------------------------------------------------------------------------------------------------------------------?><testgrp
><title
>Diagnostic Test</title><spec
><ptxt
><testno><emph>1.</emph></testno> <emph
>O2 SENSOR BELOW 2.52 VOLTS</emph></ptxt></spec><test1
><ptxt
>Start the engine.</ptxt></test1><test1
><ptxt
>Allow the engine to reach normal operating temperature.</ptxt></test1><test1
><ptxt
>With a scan tool, read the 1/1 O2 Sensor voltage.</ptxt></test1><question
>Is the voltage below 2.52 volts?</question><result
>Yes</result><action
><list1
><item
><ptxt
>Go To <intxref
refid="c7d242fde1d14c7ea1823a6813551afa"
>2</intxref></ptxt></item></list1></action><result
>No</result><action
><list1
><item
><ptxt
>Refer to the INTERMITTENT CONDITION Diagnostic Procedure.</ptxt></item><item
><ptxt
>Perform the POWERTRAIN VERIFICATION TEST. <extxref
document="SOFTLINK"
extrefid="0900000360"
>(Refer to 9 - ENGINE - STANDARD PROCEDURE)</extxref> <symbol
name="SKIP"
></symbol> </ptxt></item></list1></action></testgrp><?STEP 2------------------------------------------------------------------------------------------------------------------------------------------------------------------------------?><testgrp
id="c7d242fde1d14c7ea1823a6813551afa"
><spec
><ptxt
><testno><emph>2.</emph></testno> <emph
>(K41) O2 SENSOR 1/1 SIGNAL CIRCUIT</emph></ptxt></spec><test1
><ptxt
>Turn the ignition off.</ptxt></test1><test1
><ptxt
>Disconnect the 1/1 O2 Sensor harness connector.</ptxt></test1><test1
><ptxt
>Ignition on, engine not running.</ptxt></test1><test1
><ptxt
>With a scan tool, monitor the O2 Sensor voltage.</ptxt></test1><question
>Is the 1/1 O2 Sensor voltage above 4.8 volts?</question><result
>Yes</result><action
><list1
><item
><ptxt
>Go To <intxref
refid="hc908bbcdf084465a9d86130558d7608"
>3</intxref></ptxt></item></list1></action><result
>No</result><action
><list1
><item
><ptxt
>Go To <intxref
refid="kb837e35e74a44849c01a5190f7ea38b"
>5</intxref><symbol
name="SKIP"
></symbol></ptxt></item></list1></action></testgrp><?STEP 3------------------------------------------------------------------------------------------------------------------------------------------------------------------------------?><testgrp
id="hc908bbcdf084465a9d86130558d7608"
><spec
><ptxt
><testno><emph>3.</emph></testno> <emph
>O2 SENSOR</emph></ptxt></spec><figure
figtype="1-column-portrait-no-fig-id"
id="nb2fa26d32d740f09885bd8716c94023"
><graphic
graphicname="7a02573b"
></graphic></figure><test1
><ptxt
>Measure the voltage on the (K902) O2 Return Upstream circuit in the O2 Sensor harness connector.</ptxt></test1><question
>Is the voltage at 2.5 volts?</question><result
>Yes</result><action
><list1
><item
><ptxt
>Replace the O2 Sensor.</ptxt></item><item
><ptxt
>Perform the POWERTRAIN VERIFICATION TEST. <extxref
document="SOFTLINK"
extrefid="0900000360"
>(Refer to 9 - ENGINE - STANDARD PROCEDURE)</extxref> </ptxt></item></list1></action><result
>No</result><action
><list1
><item
><ptxt
>Go To <intxref
refid="j58c9c71edf941f2b4c413492c295776"
>4</intxref><symbol
name="SKIP"
></symbol></ptxt></item></list1></action></testgrp><?STEP 4------------------------------------------------------------------------------------------------------------------------------------------------------------------------------?><testgrp
id="j58c9c71edf941f2b4c413492c295776"
><spec
><ptxt
><testno><emph>4.</emph></testno> <emph
>(K902) O2 RETURN UPSTREAM CIRCUIT SHORTED TO GROUND</emph></ptxt></spec><figure
figtype="1-column-portrait-no-fig-id"
id="kd81bd2cdd974f53bcec7be7049b4783"
><graphic
graphicname="7a02573c"
></graphic></figure><test1
><ptxt
>Turn the ignition off.</ptxt></test1><test1
><ptxt
>Disconnect the C2 PCM harness connector.</ptxt></test1><test1
><ptxt
>Measure the resistance between ground and the (K902) O2 Return Upstream circuit in the O2 Sensor harness connector.</ptxt></test1><question
>Is the resistance below 100 ohms?</question><result
>Yes</result><action
><list1
><item
><ptxt
>Repair the short to ground in the (K902) O2 Return Upstream circuit.</ptxt></item><item
><ptxt
>Perform the POWERTRAIN VERIFICATION TEST. <extxref
document="SOFTLINK"
extrefid="0900000360"
>(Refer to 9 - ENGINE - STANDARD PROCEDURE)</extxref> </ptxt></item></list1></action><result
>No</result><action
><list1
><item
><ptxt
>Go To <intxref
refid="k52fd3fceee049b6b522d657934d0796"
>8</intxref><symbol
name="SKIP"
></symbol></ptxt></item></list1></action></testgrp><?STEP 5-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------?><testgrp
id="kb837e35e74a44849c01a5190f7ea38b"
><spec
><ptxt
><testno><emph>5.</emph></testno> <emph
>(K41) O2 SENSOR 1/1 SIGNAL CIRCUIT SHORTED TO GROUND</emph></ptxt></spec><figure
figtype="1-column-portrait-no-fig-id"
id="o6117fb27b2f42e59f64ec77f8f13cd7"
><graphic
graphicname="7a02573d"
></graphic></figure><test1
><ptxt
>Turn the ignition off.</ptxt></test1><test1
><ptxt
>Disconnect the C2 PCM harness connector.</ptxt></test1><test1
><ptxt
>Measure the resistance between ground and the (K41) O2 Sensor 1/1 Signal circuit in the O2 Sensor harness connector.</ptxt></test1><question
>Is the resistance below 100 ohms?</question><result
>Yes</result><action
><list1
><item
><ptxt
>Repair the short to ground in the (K41) O2 Sensor 1/1 Signal circuit.</ptxt></item><item
><ptxt
>Perform the POWERTRAIN VERIFICATION TEST. <extxref
document="SOFTLINK"
extrefid="0900000360"
>(Refer to 9 - ENGINE - STANDARD PROCEDURE)</extxref> </ptxt></item></list1></action><result
>No</result><action
><list1
><item
><ptxt
>Go To <intxref
refid="la6fc984afc749bea4fec9e4b00820e8"
>6</intxref><symbol
name="SKIP"
></symbol></ptxt></item></list1></action></testgrp><?STEP 6------------------------------------------------------------------------------------------------------------------------------------------------------------------------------?><testgrp
id="la6fc984afc749bea4fec9e4b00820e8"
><spec
><ptxt
><testno><emph>6.</emph></testno> <emph
>(K41) O2 SENSOR 1/1 SIGNAL CIRCUIT SHORTED TO THE (K902) O2 RETURN UPSTREAM CIRCUIT </emph></ptxt></spec><figure
figtype="1-column-portrait-no-fig-id"
id="o033a15ecf9e43be8fadc0eeb9f2a17b"
><graphic
graphicname="7a02573e"
></graphic></figure><test1
><ptxt
>Measure the resistance between the (K41) O2 Sensor 1/1 Signal circuit and the (K902) O2 Return Upstream circuit in the O2 Sensor harness connector.</ptxt></test1><question
>Is the resistance below 100 ohms?</question><result
>Yes</result><action
><list1
><item
><ptxt
>Repair the short between the (K902) O2 Return Upstream circuit and the (K41) O2 Sensor 1/1 Signal circuit.</ptxt></item><item
><ptxt
>Perform the POWERTRAIN VERIFICATION TEST. <extxref
document="SOFTLINK"
extrefid="0900000360"
>(Refer to 9 - ENGINE - STANDARD PROCEDURE)</extxref> </ptxt></item></list1></action><result
>No</result><action
><list1
><item
><ptxt
>Go To <intxref
refid="g9f30e6a96224d9c81120af2495b0530"
>7</intxref><symbol
name="SKIP"
></symbol></ptxt></item></list1></action></testgrp><?STEP 7------------------------------------------------------------------------------------------------------------------------------------------------------------------------------?><testgrp
id="g9f30e6a96224d9c81120af2495b0530"
><spec
><ptxt
><testno><emph>7.</emph></testno> <emph
>(K41) O2 SENSOR 1/1 SIGNAL CIRCUIT SHORTED TO THE (Z906) O2 1/1 HEATER GROUND CIRCUIT </emph></ptxt></spec><figure
figtype="1-column-portrait-no-fig-id"
id="c3e0cd80015f448ba83631a5fdd41588"
><graphic
graphicname="7a02573f"
></graphic></figure><test1
><ptxt
>Measure the resistance between the (K41) O2 Sensor 1/1 Signal circuit and the (Z906) O2 1/1 Heater ground circuit in the O2 Sensor harness connector.</ptxt></test1><question
>Is the resistance below 100 ohms?</question><result
>Yes</result><action
><list1
><item
><ptxt
>Repair the short between the (Z906) O2 1/1 Heater ground circuit and the (K41) O2 Sensor 1/1 Signal circuit.</ptxt></item><item
><ptxt
>Perform the POWERTRAIN VERIFICATION TEST. <extxref
document="SOFTLINK"
extrefid="0900000360"
>(Refer to 9 - ENGINE - STANDARD PROCEDURE)</extxref> </ptxt></item></list1></action><result
>No</result><action
><list1
><item
><ptxt
>Go To <intxref
refid="k52fd3fceee049b6b522d657934d0796"
>8</intxref><symbol
name="SKIP"
></symbol></ptxt></item></list1></action></testgrp><?STEP 8------------------------------------------------------------------------------------------------------------------------------------------------------------------------------?><testgrp
id="k52fd3fceee049b6b522d657934d0796"
><spec
><ptxt
><testno><emph>8.</emph></testno> <emph
>PCM </emph></ptxt></spec><attention3
name="NOTE"
><ptxt
>Before continuing, check the PCM harness connector terminals for corrosion, damage, or terminal push out. Repair as necessary.</ptxt></attention3><test1
><ptxt
>Using the schematics as a guide, inspect the wire harness and connectors. Pay particular attention to all Power and Ground circuits.</ptxt></test1><question
>Were there any problems found?</question><result
>Yes</result><action
><list1
><item
><ptxt
>Repair as necessary.</ptxt></item><item
><ptxt
>Perform the POWERTRAIN VERIFICATION TEST. <extxref
document="SOFTLINK"
extrefid="0900000360"
>(Refer to 9 - ENGINE - STANDARD PROCEDURE)</extxref> </ptxt></item></list1></action><result
>No</result><action
><list1
><item
><ptxt
>Replace and program the Powertrain Control Module per Service Information.</ptxt></item><item
><ptxt
>Perform the POWERTRAIN VERIFICATION TEST. <extxref
document="SOFTLINK"
extrefid="0900000360"
>(Refer to 9 - ENGINE - STANDARD PROCEDURE)</extxref> <symbol
name="SKIP"
></symbol></ptxt></item></list1></action></testgrp></diagnostic></servinfo>