><title
>B1032–EVAPORATOR FIN TEMPERATURE SENSOR CIRCUIT HIGH (CCN)</title><figure
figtype="2-column-portrait-no-fig-id"
id="gcd301fa03e0476a9c996bc7001ababe"
><graphic
graphicname="7a033b20"
></graphic></figure><para
><ptxt
>For a complete wiring diagram <emph
>Refer to Section 8W</emph>.</ptxt></para><diagnostic
type="condition"
><condition
><spec
><list1
><item
><ptxt
><emph
>When Monitored:</emph></ptxt><para
><ptxt
>With the ignition on.</ptxt></para></item><item
><ptxt
><emph
>Set Condition:</emph></ptxt><para
><ptxt
>If the Evaporator Temperature Sensor input is out of range toward the high voltage threshold.</ptxt></para></item></list1><table
><tgroup
xmlns:fo="http://www.w3.org/1999/XSL/Format"
xmlns:saxon="http://icl.com/saxon"
border-width.conditionality="retain"
font-size="7pt"
width="100%"
border-collapse="collapse-with-precedence"
table-omit-header-at-break="false"
border-width="1pt"
border-color="black"
border-style="solid"
space-after="6pt"
table-layout="fixed"
><table-column
column-number="1"
column-width="proportional-column-width(396)"
></table-column><thead
><row
><entry
valign="bottom"
align="center"
><ptxt
><emph
>Possible Causes</emph></ptxt></entry></row></thead><tbody
><row
><entry
valign="top"
align="left"
><ptxt
>(C21) EVAPORATOR TEMPERATURE SENSOR SIGNAL CIRCUIT SHORTED TO VOLTAGE</ptxt></entry></row><row
><entry
valign="top"
align="left"
><ptxt
>(C21) EVAPORATOR TEMPERATURE SENSOR SIGNAL CIRCUIT OPEN</ptxt></entry></row><row
><entry
valign="top"
align="left"
><ptxt
>(C121) SENSOR GROUND CIRCUIT OPEN</ptxt></entry></row><row
><entry
valign="top"
align="left"
><ptxt
>EVAPORATOR TEMPERATURE SENSOR</ptxt></entry></row><row
><entry
valign="top"
align="left"
><ptxt
>INSTRUMENT CLUSTER (CCN)</ptxt></entry></row></tbody></tgroup></table></spec></condition></diagnostic><diagnostic
type="test"
id="o0224559784446a0a0245b2dc12e6d82"
><?STEP 1------------------------------------------------------------------------------------------------------------------------------------------------------------------------------?><testgrp
id="n8c4c19a7be84fc69d01cfcbc10a1f6b"
><title
>Diagnostic Test</title><spec
><ptxt
><testno><emph>1.</emph></testno> <emph
>VERIFY B1032–EVAPORATOR FIN TEMPERATURE SENSOR CIRCUIT HIGH IS ACTIVE</emph></ptxt></spec><test1
><ptxt
>Turn the ignition on.</ptxt></test1><test1
><ptxt
>With the scan tool, erase DTCs.</ptxt></test1><test1
><ptxt
>Turn the ignition off, wait 10 seconds, and turn the ignition on.</ptxt></test1><test1
><ptxt
>With the scan tool, read DTCs.</ptxt></test1><question
>Does the scan tool display this DTC as active?</question><result
>Yes</result><action
><list1
><item
><ptxt
>Go To <intxref
refid="bcb12e1ddb624f7ea23e9bb7fc0faf0f"
>2</intxref></ptxt></item></list1></action><result
>No</result><action
><list1
><item
><ptxt
>Check for an intermittent condition by inspecting the related wiring harness for chafed, pierced, pinched, and partially broken wires. Also, inspect the related
connectors for broken, bent, pushed out, spread, corroded, or contaminated terminals. Repair as necessary.</ptxt></item><item
><ptxt
>Perform the BODY VERIFICATION TEST – VER 1. <extxref
document="SOFTLINK"
extrefid="0857000360"
>(Refer to 8 - ELECTRICAL/ELECTRONIC CONTROL MODULES - STANDARD PROCEDURE)</extxref>.<symbol
name="skip"
></symbol></ptxt></item></list1></action></testgrp><?STEP 2------------------------------------------------------------------------------------------------------------------------------------------------------------------------------?><testgrp
id="bcb12e1ddb624f7ea23e9bb7fc0faf0f"
><spec
><ptxt
><testno><emph>2.</emph></testno> <emph
>CHECK FOR DTC WITH THE EVAPORATOR TEMPERATURE SENSOR HARNESS CONNECTOR DISCONNECTED</emph></ptxt></spec><figure
figtype="1-column-portrait-no-fig-id"
id="h2843cf218cc4ec3b73bed8aa34d579c"
><graphic
graphicname="7a033b21"
></graphic></figure><test1
><ptxt
>Turn the ignition off.</ptxt></test1><test1
><ptxt
>Disconnect the Evaporator Temperature Sensor harness connector.</ptxt></test1><test1
><ptxt
>Turn the ignition on.</ptxt></test1><test1
><ptxt
>With the scan tool, erase DTCs.</ptxt></test1><test1
><ptxt
>Turn the ignition off, wait 10 seconds, and turn the ignition on.</ptxt></test1><test1
><ptxt
>With the scan tool, read DTCs.</ptxt></test1><question
>Does the scan tool display this DTC as active?</question><result
>Yes</result><action
><list1
><item
><ptxt
>Go To <intxref
refid="n7df375ebd224727901dbd6b9c02f33c"
>3</intxref>.</ptxt></item></list1></action><result
>No</result><action
><list1
><item
><ptxt
>Replace the Evaporator Temperature Sensor in accordance with the service information.</ptxt></item><item
><ptxt
>Perform BODY VERIFICATION TEST - VER 1. <extxref
document="SOFTLINK"
extrefid="0857000360"
> (Refer to 8 - ELECTRICAL/ELECTRONIC CONTROL MODULES - STANDARD PROCEDURE)</extxref>.<symbol
name="skip"
></symbol></ptxt></item></list1></action></testgrp><?STEP 3------------------------------------------------------------------------------------------------------------------------------------------------------------------------------?><testgrp
id="n7df375ebd224727901dbd6b9c02f33c"
><spec
><ptxt
><testno><emph>3.</emph></testno> <emph
>CHECK (C21) EVAPORATOR TEMPERATURE SENSOR SIGNAL CIRCUIT FOR AN OPEN</emph></ptxt></spec><figure
figtype="1-column-portrait-no-fig-id"
id="l8dcb45154e448b19100eeb7ea8d6702"
><graphic
graphicname="7a033b22"
></graphic></figure><test1
><ptxt
>Disconnect the Instrument Cluster (CCN) C3 harness connector.</ptxt></test1><test1
><ptxt
>Measure the resistance of the (C21) Evaporator Temperature Sensor Signal circuit between the Instrument Cluster (CCN) C3 harness connector and the Evaporator Temperature Sensor harness connector.</ptxt></test1><question
>Does the ohm meter read open circuit?</question><result
>Yes</result><action
><list1
><item
><ptxt
>Repair the (C21) Evaporator Temperature Sensor Signal circuit for an open.</ptxt></item><item
><ptxt
>Perform BODY VERIFICATION TEST - VER 1. <extxref
document="SOFTLINK"
extrefid="0857000360"
> (Refer to 8 - ELECTRICAL/ELECTRONIC CONTROL MODULES - STANDARD PROCEDURE)</extxref>.</ptxt></item></list1></action><result
>No</result><action
><list1
><item
><ptxt
>Go To <intxref
refid="n6e4fc62f7974874a17b3b8fde04d7b1"
>5</intxref>.<symbol
name="skip"
></symbol></ptxt></item></list1></action></testgrp><?STEP 4------------------------------------------------------------------------------------------------------------------------------------------------------------------------------?><testgrp
id="ac0cc0d49b584d97bc3c806bc25f751d"
><spec
><ptxt
><testno><emph>4.</emph></testno> <emph
>CHECK (C21) EVAPORATOR TEMPERATURE SENSOR SIGNAL CIRCUIT FOR SHORT TO VOLTAGE</emph></ptxt></spec><figure
figtype="1-column-portrait-no-fig-id"
id="m3c79459e4b84bf3b2ef0e4f7dc2c786"
><graphic
graphicname="7a033b23"
></graphic></figure><test1
><ptxt
>Using a volt meter check for voltage on the (C21) Evaporator Temperature Sensor Signal circuit.</ptxt></test1><question
>Does the volt meter read any voltage?</question><result
>Yes</result><action
><list1
><item
><ptxt
>Repair the (C21) Evaporator Temperature Sensor Signal circuit for a short to voltage.</ptxt></item><item
><ptxt
>Perform BODY VERIFICATION TEST - VER 1. <extxref
document="SOFTLINK"
extrefid="0857000360"
> (Refer to 8 - ELECTRICAL/ELECTRONIC CONTROL MODULES - STANDARD PROCEDURE)</extxref>.</ptxt></item></list1></action><result
>No</result><action
><list1
><item
><ptxt
>Go To <intxref
refid="n6e4fc62f7974874a17b3b8fde04d7b1"
>5</intxref>.<symbol
name="skip"
></symbol></ptxt></item></list1></action></testgrp><?STEP 5------------------------------------------------------------------------------------------------------------------------------------------------------------------------------?><testgrp
id="n6e4fc62f7974874a17b3b8fde04d7b1"
><spec
><ptxt
><testno><emph>5.</emph></testno> <emph
>CHECK (C121) SENSOR GROUND CIRCUIT FOR AN OPEN</emph></ptxt></spec><figure
figtype="1-column-portrait-no-fig-id"
id="oa5ea80f15144d5ca17e676f4e5fefd9"
><graphic
graphicname="7a033b24"
></graphic></figure><test1
><ptxt
>Measure the resistance of the (C121) Sensor Ground circuit between the Instrument Cluster (CCN) C3 harness connector and the Evaporator Temperature Sensor harness connector.</ptxt></test1><question
>Does the ohm meter read open circuit?</question><result
>Yes</result><action
><list1
><item
><ptxt
>Replace the Instrument Cluster (CCN) in accordance with the service information.</ptxt></item><item
><ptxt
>Perform BODY VERIFICATION TEST - VER 1. <extxref
document="SOFTLINK"
extrefid="0857000360"
> (Refer to 8 - ELECTRICAL/ELECTRONIC CONTROL MODULES - STANDARD PROCEDURE)</extxref>.</ptxt></item></list1></action><result
>No</result><action
><list1
><item
><ptxt
>Repair the (C121) Sensor Ground circuit for an open.</ptxt></item><item
><ptxt
>Perform BODY VERIFICATION TEST - VER 1. <extxref
document="SOFTLINK"
extrefid="0857000360"
> (Refer to 8 - ELECTRICAL/ELECTRONIC CONTROL MODULES - STANDARD PROCEDURE)</extxref>.<symbol
name="skip"
></symbol></ptxt></item></list1></action></testgrp></diagnostic></servinfo>