>HOUSING-AIR INLET</title><attention3
name="NOTE"
><ptxt
>LHD model with A/C shown in illustrations. RHD and heater-only models similar.</ptxt></attention3><figure
figtype="1-column-portrait-no-fig-id"
id="c20fd61579d84b1d962dbdc32f07aba9"
><graphic
graphicname="7a033b45"
></graphic></figure><s1
><ptxt
>Carefully install the recirculation-air door into the air inlet housing (2) by pinching the two ends of the air-door together and aligning the pivot shafts of the air-door to the pivot shaft holes
in the air inlet housing.</ptxt></s1><attention3
name="NOTE"
><ptxt
>Install the recirculation door pivot shaft adapter by carefully pushing it straight into the end of the recirculation door pivot shaft.</ptxt></attention3><s1
><ptxt
>Install the recirculation door pivot shaft adapter (1) into the right side pivot shaft of the recirculation air-door. Make sure the adapter is fully engaged to the pivot shaft.<symbol
name="skip"
></symbol></ptxt></s1><figure
figtype="1-column-portrait-no-fig-id"
id="id220a58bf044db1a48c990c3050bc14"
><graphic
graphicname="7a033b27"
></graphic></figure><s1
><ptxt
>Install the recirculation door actuator (2) onto the right side of the air inlet housing (1). If necessary, rotate the actuator slightly to align the splines of the actuator output shaft (3) with
those on the recirculation door pivot shaft adapter (4).<symbol
name="skip"
></symbol></ptxt></s1><figure
figtype="1-column-portrait-no-fig-id"
id="j0b17264edcb4e5eb73db71c5fe23362"
><graphic
graphicname="7a033b44"
></graphic></figure><s1
><ptxt
>Install the two screws (1) that secure the recirculation door actuator (3) to the air inlet housing (2). Tighten the screws to 1.2 N·m (10 in. lbs.).<symbol
name="skip"
></symbol></ptxt></s1><figure
figtype="1-column-portrait-no-fig-id"
id="f8d09237b93d47c1977611be9cc03985"
><graphic
graphicname="7a033b35"
></graphic></figure><s1
><ptxt
>Install the air inlet housing (2) onto the HVAC housing (1) <extxref
document="SOFTLINK"
extrefid="2404019420"
>(refer to 24 - HEATING &amp; AIR CONDITIONING/DISTRIBUTION/HOUSING-HVAC
- HOUSING- AIR INLET - INSTALLATION)</extxref>.</ptxt></s1><s1
><ptxt
>Install the HVAC housing assembly <extxref
document="SOFTLINK"
extrefid="2404019420"
>(refer to 24 - HEATING &amp; AIR CONDITIONING/DISTRIBUTION/HOUSING-HVAC - HOUSING-HVAC ASSEMBLY
- INSTALLATION)</extxref>.<symbol