>BATTERY</title><para
><ptxt
>The battery Group Size number, the Cold Cranking Amperage (CCA) rating, and the Reserve Capacity (RC) rating or Ampere-Hours (AH) rating can be found on the original equipment battery label.
Be certain that a replacement battery has the correct Group Size number, as well as CCA, and RC or AH ratings that equal or exceed the original equipment specification for the vehicle being serviced. Battery
sizes and ratings are discussed in more detail below.</ptxt></para><attention3
name="NOTE"
><ptxt
>Vehicles equipped with a diesel engine utilize a unique battery. The specifications for this battery may differ from the standards shown here. Refer to the battery manufacturer
for detailed specifications.</ptxt></attention3><list1
type="ordered"
enumtype="bullet"
id="objid-080022dc80d32bee-2"
><item
><ptxt
><emph
>Group Size</emph> - The outside dimensions and terminal placement of the battery conform to standards established by the Battery Council International (BCI). Each battery is assigned a
BCI Group Size number to help identify a correctly-sized replacement.</ptxt></item><item
><ptxt
><emph
>Cold Cranking Amperage</emph> - The Cold Cranking Amperage (CCA) rating specifies how much current (in amperes) the battery can deliver for thirty seconds at -18° C (0° F). Terminal
voltage must not fall below 7.2 volts during or after the thirty second discharge period. The CCA required is generally higher as engine displacement increases, depending also upon the starter current draw
requirements.</ptxt></item><item
><ptxt
><emph
>Reserve Capacity</emph> - The Reserve Capacity (RC) rating specifies the time (in minutes) it takes for battery terminal voltage to fall below 10.5 volts, at a discharge rate of 25 amperes.
RC is determined with the battery fully-charged at 26.7° C (80° F). This rating estimates how long the battery might last after a charging system failure, under minimum electrical load.</ptxt></item><item
><ptxt
><emph
>Ampere-Hours</emph> - The Ampere-Hours (AH) rating specifies the current (in amperes) that a battery can deliver steadily for twenty hours, with the voltage in the battery not falling
below 10.5 volts. This rating is also sometimes identified as the twenty-hour discharge rating.</ptxt></item><item
><ptxt
><emph
>Load Test Amperage</emph> - The Load Test Amperage rating specifies the current (in amperes) that a battery should be tested at with the battery load test equipment. This value should
always be 50 percent of the CCA. For example: if the CCA for this battery is 700 amps, the Load Test Amperage is 50 percent of that or 350 amps.</ptxt></item></list1><table
frame="all"
pgwide="1"
id="objid-080022dc80d32bee-3"
><tgroup
xmlns:fo="http://www.w3.org/1999/XSL/Format"
xmlns:saxon="http://icl.com/saxon"
border-width.conditionality="retain"
font-size="7pt"
width="100%"
border-collapse="collapse-with-precedence"
table-omit-header-at-break="false"
border-width="1pt"
border-color="black"
border-style="solid"
space-after="6pt"
><table-column
column-number="1"
column-width="1.28in"
border-end-width="1pt"
border-end-color="black"
border-end-style="solid"
></table-column><table-column
column-number="2"
column-width="1.32in"
border-end-width="1pt"
border-end-color="black"
border-end-style="solid"
></table-column><table-column
column-number="3"
column-width="1.15in"
border-end-width="1pt"
border-end-color="black"
border-end-style="solid"
></table-column><table-column
column-number="4"
column-width="1.25in"
border-end-width="1pt"
border-end-color="black"
border-end-style="solid"
></table-column><table-column
column-number="5"
column-width="1.13in"
border-end-width="1pt"
border-end-color="black"
border-end-style="solid"
></table-column><table-column
column-number="6"
column-width="1.13in"
></table-column><thead
><row
><entry
valign="middle"
align="center"
colspan="6"
><ptxt
>BATTERY CLASSIFICATIONS &amp; RATINGS</ptxt></entry><entry
></entry><entry
></entry><entry
></entry><entry
></entry><entry
></entry></row><row
><entry
valign="middle"
align="center"
><ptxt
>Part Number</ptxt></entry><entry
valign="middle"
align="center"
><ptxt
>BCI Group Size Classification</ptxt></entry><entry
valign="middle"
align="center"
><ptxt
>Cold Cranking Amperage</ptxt></entry><entry
valign="middle"
align="center"
><ptxt
>Reserve Capacity</ptxt></entry><entry
valign="middle"
align="center"
><ptxt
>Ampere - Hours</ptxt></entry><entry
valign="middle"
align="center"
><ptxt
>Load Test Amperage</ptxt></entry></row></thead><tbody
><row
><entry
valign="middle"
align="center"
><ptxt
>04609365AE</ptxt></entry><entry
valign="middle"
align="center"
><ptxt
>34</ptxt></entry><entry
valign="middle"
align="center"
><ptxt
>600</ptxt></entry><entry
valign="middle"
align="center"
><ptxt
>120 Minutes</ptxt></entry><entry
valign="middle"
align="center"
><ptxt
>66</ptxt></entry><entry
valign="middle"
align="center"
><ptxt
>300</ptxt></entry></row><row
><entry
valign="middle"
align="center"
><ptxt
>04727475AC</ptxt></entry><entry
valign="middle"
align="center"
><ptxt
>31</ptxt></entry><entry
valign="middle"
align="center"
><ptxt
>825</ptxt></entry><entry
valign="middle"
align="center"
><ptxt
>140 Minutes</ptxt></entry><entry
valign="middle"
align="center"
><ptxt
>50</ptxt></entry><entry
valign="middle"
align="center"
><ptxt