<?xml version="1.0"?>
<?xml-stylesheet type="text/xsl" href="./twl_formatc.xsl"?>
<servinfo
releasenbr="1"
update="original"
id="objid-080022dc819aa676-1"
><title
>B1288-TRIP/TOGGLE SWITCH PERFORMANCE</title><para
><ptxt
>For a complete wiring diagram <emph
>Refer to Section 8W</emph>.</ptxt></para><diagnostic
type="condition"
><condition
><spec
><list1
><item
><ptxt
><emph
>When Monitored:</emph></ptxt><para
><ptxt
>With the ignition on.</ptxt></para></item><item
><ptxt
><emph
>Set Condition:</emph></ptxt><para
><ptxt
>The Instrument Cluster detects the Trip/Toggle Switch active for greater than 20 seconds.</ptxt></para></item></list1><table
><tgroup
xmlns:fo="http://www.w3.org/1999/XSL/Format"
xmlns:saxon="http://icl.com/saxon"
border-width.conditionality="retain"
font-size="7pt"
width="100%"
border-collapse="collapse-with-precedence"
table-omit-header-at-break="false"
border-width="1pt"
border-color="black"
border-style="solid"
space-after="6pt"
table-layout="fixed"
><table-column
column-number="1"
column-width="proportional-column-width(396)"
></table-column><thead
><row
><entry
valign="bottom"
align="center"
><ptxt
><emph
>Possible Causes</emph></ptxt></entry></row></thead><tbody
><row
><entry
valign="top"
align="left"
><ptxt
>INSTRUMENT CLUSTER</ptxt></entry></row></tbody></tgroup></table></spec></condition></diagnostic><diagnostic
type="test"
><?STEP 1------------------------------------------------------------------------------------------------------------------------------------------------------------------------------?><testgrp
><title
>Diagnostic Test</title><spec
><ptxt
><testno><emph>1.</emph></testno> <emph
>CHECK FOR AN ACTIVE DTC</emph></ptxt></spec><test1
><ptxt
>Turn the ignition on.</ptxt></test1><test1
><ptxt
>With the scan tool, record and erase DTCs.</ptxt></test1><test1
><ptxt
>Press the Trip/Toggle switch three times.</ptxt></test1><test1
><ptxt
>With the scan tool, read DTCs.</ptxt></test1><question
>Does the scan tool display this DTC as active?</question><result
>Yes</result><action
><list1
><item
><ptxt
>Replace the Instrument Cluster in accordance with the service information.</ptxt></item><item
><ptxt
>Perform BODY VERIFICATION TEST - VER 1. <extxref
document="SOFTLINK"
extrefid="0857000360"
>(Refer to 8 - ELECTRICAL/ELECTRONIC CONTROL MODULES - STANDARD PROCEDURE)</extxref> </ptxt></item></list1></action><result
>No</result><action
><list1
><item
><ptxt
>Test complete<symbol
name="skip"
></symbol></ptxt></item></list1></action></testgrp></diagnostic></servinfo>