<?xml version="1.0"?>
<?xml-stylesheet type="text/xsl" href="./twl_formatc.xsl"?>
<servinfo
releasenbr="1"
update="original"
id="g0503fad55aa4a89b3c6cec1e2ffa0f0"
><title
>P0673-CYLINDER 3 GLOW PLUG CIRCUIT</title><figure
figtype="2-column-portrait-no-fig-id"
id="f33a110282a6484fa5cbc3a1b83e49fa"
><graphic
graphicname="7a036c34"
></graphic></figure><para
><ptxt
>For a complete wiring diagram <emph
>Refer to Section 8W</emph></ptxt></para><diagnostic
type="condition"
><condition
><spec
><list1
><item
><ptxt
><emph
>When Monitored:</emph></ptxt><para
><ptxt
>With the ignition on and the Glow Plug Module Glow Plug command on.</ptxt></para></item><item
><ptxt
><emph
>Set Condition:</emph></ptxt><para
><ptxt
>The ECM detects an open or short on the Cylinder 3 Glow Plug circuit for 0.5 seconds.</ptxt></para></item></list1><table
><tgroup
xmlns:fo="http://www.w3.org/1999/XSL/Format"
xmlns:saxon="http://icl.com/saxon"
border-width.conditionality="retain"
font-size="7pt"
width="100%"
border-collapse="collapse-with-precedence"
table-omit-header-at-break="false"
border-width="1pt"
border-color="black"
border-style="solid"
space-after="6pt"
table-layout="fixed"
><table-column
column-number="1"
column-width="proportional-column-width(396)"
></table-column><thead
><row
><entry
valign="bottom"
align="center"
><ptxt
><emph
>Possible Causes</emph></ptxt></entry></row></thead><tbody
><row
><entry
valign="top"
align="left"
><ptxt
>INTERMITTENT DTC</ptxt></entry></row><row
><entry
valign="top"
align="left"
><ptxt
>(A204) GLOW PLUG 3 CONTROL CIRCUIT OPEN</ptxt></entry></row><row
><entry
valign="top"
align="left"
><ptxt
>(A204) GLOW PLUG 3 CONTROL CIRCUIT SHORTED TO GROUND</ptxt></entry></row><row
><entry
valign="top"
align="left"
><ptxt
>(A204) GLOW PLUG 3 CONTROL CIRCUIT SHORTED TO VOLTAGE</ptxt></entry></row><row
><entry
valign="top"
align="left"
><ptxt
>GLOW PLUG 3</ptxt></entry></row><row
><entry
valign="top"
align="left"
><ptxt
>GLOW PLUG MODULE</ptxt></entry></row></tbody></tgroup></table></spec><para
><ptxt
><emph
>Always perform the Pre-Diagnostic Troubleshooting procedure before proceeding.<extxref
document="SOFTLINK"
extrefid="0900000030"
>(Refer to 9 - ENGINE - DIAGNOSIS AND TESTING)</extxref></emph></ptxt></para></condition></diagnostic><diagnostic
type="test"
><?STEP 1------------------------------------------------------------------------------------------------------------------------------------------------------------------------------?><testgrp
id="c20b0154744944a693bfd38612ac7de7"
><title
>Diagnostic Test</title><spec
><ptxt
><testno><emph>1.</emph></testno> <emph
>CHECK FOR ACTIVE DTC</emph></ptxt></spec><test1
><ptxt
>Ignition on, engine not running.</ptxt></test1><test1
><ptxt
>With the scan tool, clear DTCs in the Engine Control Module (ECM).</ptxt></test1><test1
><ptxt
>Perform several ignition cycles leaving the ignition on for at least 10 seconds then off for 10 seconds.</ptxt></test1><test1
><ptxt
>With the scan tool, read the ECM DTCs.</ptxt></test1><question
>Did this DTC set again?</question><result
>Yes</result><action
><list1
><item
><ptxt
>Go To<intxref
refid="le52a03b38634366af646707cfd5c7c2"
>2</intxref></ptxt></item></list1></action><result
>No</result><action
><list1
><item
><ptxt
>Refer to the *CHECKING FOR AN INTERMITTENT DTC Diagnostic Procedure.<extxref
document="SOFTLINK"
extrefid="0900000030"
>(Refer to 9 - ENGINE - DIAGNOSIS
AND TESTING)</extxref><symbol
name="SKIP"
></symbol></ptxt></item></list1></action></testgrp><?STEP 2------------------------------------------------------------------------------------------------------------------------------------------------------------------------------?><testgrp
id="le52a03b38634366af646707cfd5c7c2"
><spec
><ptxt
><testno><emph>2.</emph></testno> <emph
>(A204) GLOW PLUG 3 CONTROL CIRCUIT OPEN</emph></ptxt></spec><figure
figtype="1-column-portrait-no-fig-id"
id="o66dac56d47647d7a222ca3171391838"
><graphic
graphicname="7a031e37"
></graphic></figure><test1
><ptxt
>Turn the ignition off.</ptxt></test1><test1
><ptxt
>Disconnect the Glow Plug 3 harness connector.</ptxt></test1><test1
><ptxt
>Disconnect the Glow Plug Module harness connector.</ptxt></test1><test1
><ptxt
>Measure the resistance of the (A204) Glow Plug 3 Control circuit between the Glow Plug 3 harness connector and the Glow Plug Module harness connector.</ptxt></test1><question
>Is the resistance below 10.0 ohms?</question><result
>Yes</result><action
><list1
><item
><ptxt
>Go To<intxref
refid="dbc4d745320242519c5ceed39c384e90"
>3</intxref></ptxt></item></list1></action><result
>No</result><action
><list1
><item
><ptxt
>Repair the (A204) Glow Plug 3 Control circuit for an open.</ptxt></item><item
><ptxt
>Perform the ECM Verification Test Ver. 1. <extxref
document="SOFTLINK"
extrefid="0900000360"
>(Refer to 9 - ENGINE - STANDARD PROCEDURE)</extxref><symbol
name="skip"
></symbol></ptxt></item></list1></action></testgrp><?STEP 3------------------------------------------------------------------------------------------------------------------------------------------------------------------------------?><testgrp
id="dbc4d745320242519c5ceed39c384e90"
><spec
><ptxt
><testno><emph>3.</emph></testno> <emph
>(A204) GLOW PLUG 3 CONTROL CIRCUIT SHORTED TO GROUND</emph></ptxt></spec><figure
figtype="1-column-portrait-no-fig-id"
id="o57d67d0035c4f018975780bb65cccf9"
><graphic
graphicname="7a031e38"
></graphic></figure><test1
><ptxt
>Measure the resistance between ground and the (A204) Glow Plug 3 Control circuit at the Glow Plug 3 harness connector.</ptxt></test1><question
>Is the resistance below 1000 ohms?</question><result
>Yes</result><action
><list1
><item
><ptxt
>Repair the (A204) Glow Plug 3 Control circuit for a short to ground.</ptxt></item><item
><ptxt
>Perform the ECM Verification Test Ver. 1. <extxref
document="SOFTLINK"
extrefid="0900000360"
>(Refer to 9 - ENGINE - STANDARD PROCEDURE)</extxref></ptxt></item></list1></action><result
>No</result><action
><list1
><item
><ptxt
>Go To<intxref
refid="ga4b5e6f08bd415895806339b0d2d6ec"
>4</intxref><symbol
name="skip"
></symbol></ptxt></item></list1></action></testgrp><?STEP 4------------------------------------------------------------------------------------------------------------------------------------------------------------------------------?><testgrp
id="ga4b5e6f08bd415895806339b0d2d6ec"
><spec
><ptxt
><testno><emph>4.</emph></testno> <emph
>(A204) GLOW PLUG 3 CONTROL CIRCUIT SHORTED TO VOLTAGE</emph></ptxt></spec><figure
figtype="1-column-portrait-no-fig-id"
id="acd98035511b49c088778d05361ed0d8"
><graphic
graphicname="7a031e39"
></graphic></figure><test1
><ptxt
>Turn the ignition on.</ptxt></test1><test1
><ptxt
>Measure the voltage of the (A204) Glow Plug 3 Control circuit at the Glow Plug 3 harness connector.</ptxt></test1><question
>Is there voltage present on the (A204) Glow Plug 3 Control circuit?</question><result
>Yes</result><action
><list1
><item
><ptxt
>Repair the (A204) Glow Plug 3 Control circuit for a short to voltage</ptxt></item><item
><ptxt
>Perform the ECM Verification Test Ver. 1. <extxref
document="SOFTLINK"
extrefid="0900000360"
>(Refer to 9 - ENGINE - STANDARD PROCEDURE)</extxref></ptxt></item></list1></action><result
>No</result><action
><list1
><item
><ptxt
>Go To<intxref
refid="m06686073c824a3ca36ecb8f0bc0c5af"
>5</intxref><symbol
name="SKIP"
></symbol></ptxt></item></list1></action></testgrp><?STEP 5------------------------------------------------------------------------------------------------------------------------------------------------------------------------------?><testgrp
id="m06686073c824a3ca36ecb8f0bc0c5af"
><spec
><ptxt
><testno><emph>5.</emph></testno> <emph
>GLOW PLUG 3</emph></ptxt></spec><test1
><ptxt
>Turn the ignition off.</ptxt></test1><test1
><ptxt
>Refer to the Service Information and replace the Glow Plug 3.</ptxt></test1><test1
><ptxt
>Turn the ignition on.</ptxt></test1><test1
><ptxt
>With the scan tool, erase ECM DTCs.</ptxt></test1><test1
><ptxt
>Perform several ignition key cycles leaving the ignition on for at least 10 seconds per cycle.</ptxt></test1><test1
><ptxt
>With the scan tool, read ECM DTCs.</ptxt></test1><question
>Does the scan tool display this DTC?</question><result
>Yes</result><action
><list1
><item
><ptxt
>Go to <intxref
refid="ic50c7ceebc948cea956a6746fd89ddb"
>6</intxref></ptxt></item></list1></action><result
>No</result><action
><list1
><item
><ptxt
>Test complete.</ptxt></item><item
><ptxt
>Perform the ECM Verification Test Ver. 1. <extxref
document="SOFTLINK"
extrefid="0900000360"
>(Refer to 9 - ENGINE - STANDARD PROCEDURE)</extxref><symbol
name="skip"
></symbol></ptxt></item></list1></action></testgrp><?STEP 6------------------------------------------------------------------------------------------------------------------------------------------------------------------------------?><testgrp
id="ic50c7ceebc948cea956a6746fd89ddb"
><spec
><ptxt
><testno><emph>6.</emph></testno> <emph
>GLOW PLUG MODULE</emph></ptxt></spec><test1
><ptxt
>Using the wiring diagram/schematic as a guide, inspect the wiring and connectors between the Glow Plugs and the Glow Plug Module.</ptxt></test1><test1
><ptxt
>Look for any chafed, pierced, pinched, or partially broken wires.</ptxt></test1><test1
><ptxt
>Look for broken, bent, pushed out or corroded terminals.</ptxt></test1><test1
><ptxt
>Refer to any Technical Service Bulletins that may apply.</ptxt></test1><question
>Were any problems found?</question><result
>Yes</result><action
><list1
><item
><ptxt
>Repair as necessary.</ptxt></item><item
><ptxt
>Perform the ECM Verification Test Ver. 1. <extxref
document="SOFTLINK"
extrefid="0900000360"
>(Refer to 9 - ENGINE - STANDARD PROCEDURE)</extxref></ptxt></item></list1></action><result
>No</result><action
><list1
><item
><ptxt
>Replace the Glow Plug Module in accordance with the Service Information.</ptxt></item><item
><ptxt
>Perform the ECM Verification Test Ver. 1. <extxref
document="SOFTLINK"
extrefid="0900000360"
>(Refer to 9 - ENGINE - STANDARD PROCEDURE)</extxref><symbol
name="skip"
></symbol></ptxt></item></list1></action></testgrp></diagnostic></servinfo>