<?xml version="1.0"?>
<?xml-stylesheet type="text/xsl" href="./twl_formatc.xsl"?>
<servinfo
releasenbr="1"
update="original"
id="gdfd98fb32f64cb5a84203e21f364cd8"
><title
>P2237-O2 SENSOR 1/1 PUMP CELL CURRENT CIRCUIT OPEN</title><figure
figtype="2-column-portrait-no-fig-id"
id="b423b208d2254477a1c68dab9a12a51d"
><graphic
graphicname="7a036b9f"
></graphic></figure><para
><ptxt
>For a complete wiring diagram <emph
>Refer to Section 8W</emph></ptxt></para><diagnostic
type="condition"
><condition
><spec
><list1
><item
><ptxt
><emph
>When Monitored:</emph></ptxt><para
><ptxt
>With the ignition on and the O2 1/1 Sensor at operating temperature.</ptxt></para></item><item
><ptxt
><emph
>Set Condition:</emph></ptxt><para
><ptxt
>The ECM detects an open on the (K89) O2 1/1 Positive Current Control circuit for 2.0 seconds.</ptxt></para></item></list1><table
><tgroup
xmlns:fo="http://www.w3.org/1999/XSL/Format"
xmlns:saxon="http://icl.com/saxon"
border-width.conditionality="retain"
font-size="7pt"
width="100%"
border-collapse="collapse-with-precedence"
table-omit-header-at-break="false"
border-width="1pt"
border-color="black"
border-style="solid"
space-after="6pt"
table-layout="fixed"
><table-column
column-number="1"
column-width="proportional-column-width(396)"
></table-column><thead
><row
><entry
valign="bottom"
align="center"
><ptxt
><emph
>Possible Causes</emph></ptxt></entry></row></thead><tbody
><row
><entry
valign="top"
align="left"
><ptxt
>INTERMITTENT DTC</ptxt></entry></row><row
><entry
valign="top"
align="left"
><ptxt
>(K89) O2 1/1 POSITIVE CURRENT CONTROL CIRCUIT SHORTED TO VOLTAGE</ptxt></entry></row><row
><entry
valign="top"
align="left"
><ptxt
>(K89) O2 1/1 POSITIVE CURRENT CONTROL CIRCUIT SHORTED TO GROUND</ptxt></entry></row><row
><entry
valign="top"
align="left"
><ptxt
>(K89) O2 1/1 POSITIVE CURRENT CONTROL CIRCUIT SHORTED TO THE (F344) FUSED ASD RELAY OUTPUT 2 CIRCUIT</ptxt></entry></row><row
><entry
valign="top"
align="left"
><ptxt
>(K89) O2 1/1 POSITIVE CURRENT CONTROL CIRCUIT SHORTED TO THE (K79) O2 1/1 HEATER CONTROL CIRCUIT</ptxt></entry></row><row
><entry
valign="top"
align="left"
><ptxt
>(K89) O2 1/1 POSITIVE CURRENT CONTROL CIRCUIT OPEN OR HIGH RESISTANCE</ptxt></entry></row><row
><entry
valign="top"
align="left"
><ptxt
>OXYGEN SENSOR</ptxt></entry></row><row
><entry
valign="top"
align="left"
><ptxt
>ENGINE CONTROL MODULE (ECM)</ptxt></entry></row></tbody></tgroup></table></spec><para
><ptxt
><emph
>Always perform the Pre-Diagnostic Troubleshooting procedure before proceeding.<extxref
document="SOFTLINK"
extrefid="0900000030"
>(Refer to 9 - ENGINE - DIAGNOSIS AND TESTING)</extxref></emph></ptxt></para></condition></diagnostic><diagnostic
type="test"
><?STEP 1------------------------------------------------------------------------------------------------------------------------------------------------------------------------------?><testgrp
><title
>Diagnostic Test</title><spec
><ptxt
><testno><emph>1.</emph></testno> <emph
>DTC IS ACTIVE</emph></ptxt></spec><test1
><ptxt
>Ignition on, engine not running.</ptxt></test1><test1
><ptxt
>With the scan tool, Clear DTCs in the Engine Control Module (ECM).</ptxt></test1><test1
><ptxt
>Start the engine.</ptxt></test1><test1
><ptxt
>Allow the engine to reach normal operating temperature.</ptxt></test1><test1
><ptxt
>Monitor the scan tool for at least two minutes.</ptxt></test1><test1
><ptxt
>With the scan tool, select View DTCs.</ptxt></test1><question
>Is the status Active for this DTC?</question><result
>Yes</result><action
><list1
><item
><ptxt
>Go To <intxref
refid="d4c4ab9a81ab4aa097751da1e68163c3"
>2</intxref> </ptxt></item></list1></action><result
>No</result><action
><list1
><item
><ptxt
>Refer to the *CHECKING FOR AN INTERMITTENT DTC Diagnostic Procedure.<extxref
document="SOFTLINK"
extrefid="0900000030"
>(Refer to 9 - ENGINE - DIAGNOSIS
AND TESTING)</extxref><symbol
name="SKIP"
></symbol></ptxt></item></list1></action></testgrp><?STEP 2------------------------------------------------------------------------------------------------------------------------------------------------------------------------------?><testgrp
id="d4c4ab9a81ab4aa097751da1e68163c3"
><spec
><ptxt
><testno><emph>2.</emph></testno> <emph
>(K89) O2 1/1 POSITIVE CURRENT CONTROL CIRCUIT SHORTED TO VOLTAGE</emph></ptxt></spec><figure
figtype="1-column-portrait-no-fig-id"
id="b27b2287a5f04e88a6eac555d5d73bd5"
><graphic
graphicname="7a036ca6"
></graphic></figure><test1
><ptxt
>Turn the ignition off.</ptxt></test1><test1
><ptxt
>Disconnect the Oxygen Sensor harness connector.</ptxt></test1><test1
><ptxt
>Disconnect the Engine Control Module (ECM) harness connector.</ptxt></test1><test1
><ptxt
>Remove the ASD Relay from the TIPM.</ptxt></test1><test1
><ptxt
>Connect a jumper wire between cavity 30 and cavity 87 of the ASD Relay Connector.</ptxt></test1><test1
><ptxt
>Turn the ignition on.</ptxt></test1><test1
><ptxt
>Measure the voltage of the (K89) O2 1/1 Positive Current Control circuit in the Oxygen Sensor harness connector.</ptxt></test1><question
>Is there any voltage present?</question><result
>Yes</result><action
><list1
><item
><ptxt
>Repair the (K89) O2 1/1 Positive Current Control circuit for a short to voltage. </ptxt></item><item
><ptxt
>Perform the ECM Verification Test Ver. 1. <extxref
document="SOFTLINK"
extrefid="0900000360"
>(Refer to 9 - ENGINE - STANDARD PROCEDURE)</extxref></ptxt></item></list1></action><result
>No</result><action
><list1
><item
><ptxt
>Go to <intxref
refid="e63a390144a34b8186dddf9d49934df5"
>3</intxref><symbol
name="SKIP"
></symbol></ptxt></item></list1></action></testgrp><?STEP 3------------------------------------------------------------------------------------------------------------------------------------------------------------------------------?><testgrp
id="e63a390144a34b8186dddf9d49934df5"
><spec
><ptxt
><testno><emph>3.</emph></testno> <emph
>(K89) O2 1/1 POSITIVE CURRENT CONTROL CIRCUIT SHORTED TO GROUND</emph></ptxt></spec><figure
figtype="1-column-portrait-no-fig-id"
id="o717642693874672b81faeb8a8de26ea"
><graphic
graphicname="7a036ca7"
></graphic></figure><test1
><ptxt
>Turn the ignition off.</ptxt></test1><test1
><ptxt
>Remove the jumper wire and install the ASD Relay.</ptxt></test1><test1
><ptxt
>Measure the resistance between ground and the (K89) O2 1/1 Positive Current Control circuit in the Oxygen Sensor harness connector.</ptxt></test1><question
>Is the resistance above 1000 ohms?</question><result
>Yes</result><action
><list1
><item
><ptxt
>Go to <intxref
refid="cf552472dcd641f0bfbb66c738596c46"
>4</intxref></ptxt></item></list1></action><result
>No</result><action
><list1
><item
><ptxt
>Repair the (K89) O2 1/1 Positive Current Control circuit for a short to ground. </ptxt></item><item
><ptxt
>Perform the ECM Verification Test Ver. 1. <extxref
document="SOFTLINK"
extrefid="0900000360"
>(Refer to 9 - ENGINE - STANDARD PROCEDURE)</extxref><symbol
name="skip"
></symbol></ptxt></item></list1></action></testgrp><?STEP 4------------------------------------------------------------------------------------------------------------------------------------------------------------------------------?><testgrp
id="cf552472dcd641f0bfbb66c738596c46"
><spec
><ptxt
><testno><emph>4.</emph></testno> <emph
>(K89) O2 1/1 POSITIVE CURRENT CONTROL CIRCUIT SHORTED TO THE (F344) FUSED ASD RELAY OUTPUT 2 CIRCUIT</emph></ptxt></spec><figure
figtype="1-column-portrait-no-fig-id"
id="od49621716fd499f997e951be4d0fff7"
><graphic
graphicname="7a036ca8"
></graphic></figure><test1
><ptxt
>Measure the resistance between the (K89) O2 1/1 Positive Current Control circuit and the (F344) Fused ASD Relay Output 2 circuit in the Oxygen Sensor harness connector.</ptxt></test1><question
>Is the resistance above 1000 ohms?</question><result
>Yes</result><action
><list1
><item
><ptxt
>Go to <intxref
refid="b72e931ecce94668936f97242ff02615"
>5</intxref></ptxt></item></list1></action><result
>No</result><action
><list1
><item
><ptxt
>Repair the (K89) O2 1/1 Positive Current Control circuit for a short to the (F344) Fused ASD Relay Output 2 circuit.</ptxt></item><item
><ptxt
>Perform the ECM Verification Test Ver. 1. <extxref
document="SOFTLINK"
extrefid="0900000360"
>(Refer to 9 - ENGINE - STANDARD PROCEDURE)</extxref><symbol
name="skip"
></symbol></ptxt></item></list1></action></testgrp><?STEP 5------------------------------------------------------------------------------------------------------------------------------------------------------------------------------?><testgrp
id="b72e931ecce94668936f97242ff02615"
><spec
><ptxt
><testno><emph>5.</emph></testno> <emph
>(K89) O2 1/1 POSITIVE CURRENT CONTROL CIRCUIT SHORTED TO THE (K79) O2 1/1 HEATER CONTROL CIRCUIT</emph></ptxt></spec><figure
figtype="1-column-portrait-no-fig-id"
id="if38f31e0b434614b83956af9cd2e6a4"
><graphic
graphicname="7a036ca9"
></graphic></figure><test1
><ptxt
>Measure the resistance between the (K89) O2 1/1 Positive Current Control circuit and the (K79) O2 1/1 Heater Control circuit in the Oxygen Sensor harness connector.</ptxt></test1><question
>Is the resistance above 1000 ohms?</question><result
>Yes</result><action
><list1
><item
><ptxt
>Go to <intxref
refid="pffc2bb8d6674653a791fa85f7a54a6d"
>6</intxref></ptxt></item></list1></action><result
>No</result><action
><list1
><item
><ptxt
>Repair the (K89) O2 1/1 Positive Current Control circuit for a short to the (K79) O2 1/1 Heater Control circuit.</ptxt></item><item
><ptxt
>Perform the ECM Verification Test Ver. 1. <extxref
document="SOFTLINK"
extrefid="0900000360"
>(Refer to 9 - ENGINE - STANDARD PROCEDURE)</extxref><symbol
name="skip"
></symbol></ptxt></item></list1></action></testgrp><?STEP 6------------------------------------------------------------------------------------------------------------------------------------------------------------------------------?><testgrp
id="pffc2bb8d6674653a791fa85f7a54a6d"
><spec
><ptxt
><testno><emph>6.</emph></testno> <emph
>(K89) O2 1/1 POSITIVE CURRENT CONTROL CIRCUIT OPEN OR HIGH RESISTANCE</emph></ptxt></spec><figure
figtype="1-column-portrait-no-fig-id"
id="a059de5716de4c80b396a7ba2694a304"
><graphic
graphicname="7a036caa"
></graphic></figure><test1
><ptxt
>Measure the resistance of the (K89) O2 1/1 Positive Current Control circuit between the Oxygen Sensor harness connector and the Engine Control Module (ECM) harness connector.</ptxt></test1><question
>Is the resistance below 10.0 ohms?</question><result
>Yes</result><action
><list1
><item
><ptxt
>Go to <intxref
refid="d0e636832c5e4d078bf7781a11ac3330"
>7</intxref></ptxt></item></list1></action><result
>No</result><action
><list1
><item
><ptxt
>Repair the (K89) 02 1/1 Positive Current Control circuit for an open circuit or high resistance.</ptxt></item><item
><ptxt
>Perform the ECM Verification Test Ver. 1. <extxref
document="SOFTLINK"
extrefid="0900000360"
>(Refer to 9 - ENGINE - STANDARD PROCEDURE)</extxref><symbol
name="skip"
></symbol></ptxt></item></list1></action></testgrp><?STEP 7------------------------------------------------------------------------------------------------------------------------------------------------------------------------------?><testgrp
id="d0e636832c5e4d078bf7781a11ac3330"
><spec
><ptxt
><testno><emph>7.</emph></testno> <emph
>OXYGEN SENSOR</emph></ptxt></spec><test1
><ptxt
>Turn the ignition off.</ptxt></test1><test1
><ptxt
>Connect the Engine Control Module (ECM) harness connector.</ptxt></test1><test1
><ptxt
>Replace the Oxygen Sensor in accordance with the Service Information.</ptxt></test1><test1
><ptxt
>Start the engine.</ptxt></test1><test1
><ptxt
>Allow the engine to reach normal operating temperature.</ptxt></test1><test1
><ptxt
>Monitor the scan tool for at least two minutes.</ptxt></test1><test1
><ptxt
>With the scan tool, select View DTCs.</ptxt></test1><question
>Is the status Active for this DTC?</question><result
>Yes</result><action
><list1
><item
><ptxt
>Go to <intxref
refid="cfbd6959162846eebdff8ff5c0cd7dac"
>8</intxref></ptxt></item></list1></action><result
>No</result><action
><list1
><item
><ptxt
>Test Complete.</ptxt></item><item
><ptxt
>Perform the ECM Verification Test Ver. 1. <extxref
document="SOFTLINK"
extrefid="0900000360"
>(Refer to 9 - ENGINE - STANDARD PROCEDURE)</extxref><symbol
name="skip"
></symbol></ptxt></item></list1></action></testgrp><?STEP 8------------------------------------------------------------------------------------------------------------------------------------------------------------------------------?><testgrp
id="cfbd6959162846eebdff8ff5c0cd7dac"
><spec
><ptxt
><testno><emph>8.</emph></testno> <emph
>ENGINE CONTROL MODULE (ECM)</emph></ptxt></spec><test1
><ptxt
>Using the wiring diagram/schematic as a guide, inspect the wiring and connectors between the Oxygen Sensor and the Engine Control Module (ECM).</ptxt></test1><test1
><ptxt
>Look for any chafed, pierced, pinched, or partially broken wires.</ptxt></test1><test1
><ptxt
>Look for broken, bent, pushed out or corroded terminals.</ptxt></test1><test1
><ptxt
>Monitor the scan tool data relative to this circuit and wiggle test the wiring and connectors.</ptxt></test1><test1
><ptxt
>Look for the data to change or for the DTC to reset during the wiggle test.</ptxt></test1><test1
><ptxt
>Refer to any Technical Service Bulletins that may apply.</ptxt></test1><question
>Were any problems found?</question><result
>Yes</result><action
><list1
><item
><ptxt
>Repair as necessary.</ptxt></item><item
><ptxt
>Perform the ECM Verification Test Ver. 1. <extxref
document="SOFTLINK"
extrefid="0900000360"
>(Refer to 9 - ENGINE - STANDARD PROCEDURE)</extxref></ptxt></item></list1></action><result
>No</result><action
><list1
><item
><ptxt
>Replace the Engine Control Module (ECM) in accordance with the Service Information.</ptxt></item><item
><ptxt
>Perform the ECM Verification Test Ver. 1. <extxref
document="SOFTLINK"
extrefid="0900000360"
>(Refer to 9 - ENGINE - STANDARD PROCEDURE)</extxref><symbol
name="skip"
></symbol></ptxt></item></list1></action></testgrp></diagnostic></servinfo>